MAINTENANCE SAFETY MANUAL
If the drain is stuck open, follow these steps: Shut off the compressed air supply to the machine. Using a crescent wrench, turn the auto drain nut at the filter unit bottom counter-clockwise one turn. Press upward on the nut to release any foreign material that may be lodged, and to reseat the drain valve.
