Comprehensive Approach to Performance Improvement …
Coal to the burners is supplied by five exhauster type pulverizers (A to E), where A is the top mill, feeding the top burner elevation, and E is the bottom mill, feeding the bottom burner elevation. The excess O 2 level is measured by six O 2 probes located in two economizer gas exit ducts (three probes per duct). Unit 3 is under stringent NO x ...